Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Indian J Ophthalmol ; 2023 Aug; 71(8): 3005-3009
Article | IMSEAR | ID: sea-225171

ABSTRACT

Purpose: To compare glaucomatous from non?glaucomatous optic atrophy using optical coherence tomography (OCT) based on the measurement values of Bruch’s membrane opening minimum rim width (BMO?MRW), which is a difficult task otherwise due to their varied course of disease progression, treatment protocols, and systemic association to visual impairment. Methods: This study was conducted in 40 eyes, comprising 20 eyes with non?glaucomatous optic neuropathy (NGON) and 20 eyes with glaucomatous optic neuropathy (GON). All patients underwent a complete ophthalmic examination followed by an OCT optic disc scan to calculate the measurement of BMO?MRW. Results: The 5?fold cross?validated area under the curve for GON versus NGON from logistic regression models was 0.95 (95% confidence interval [CI]: 0.86–1.00) using BMO?MRW values from all sectors. The results revealed that the measurements were significantly lesser in GON than in NGON patients. Conclusion: Hence, OCT?based BMO?MRW values could be used as an additional test to compare glaucomatous with non?glaucomatous optic neuropathy patients, especially in cases of high clinical suspicion.

2.
Indian J Ophthalmol ; 2020 Jan; 68(1): 164-167
Article | IMSEAR | ID: sea-197735

ABSTRACT

Purpose: Technological development of optic coherence tomography has enabled a detailed assessment of the optic nerve and deeper structures and in vivo measurements. The aim of this study was to compare the lamina cribrosa morphology of the optic nerve in idiopathic intracranial hypertension (IIH) and healthy individuals. Methods: The lamina cribrosa morphology of optic nerve in 15 eyes with IIH and 17 eyes of healthy individuals were compared. Four parameters such as Bruch membrane opening (BMO), lamina cribrosa thickness (LCT), prelaminar tissue thickness (PTT), and anterior lamina cribrosa surface depth (ALCSD) were retrospectively evaluated. Results: By enhanced depth imaging-optic coherence tomography (EDI-OCT), PTT and BMO were found to be significantly greater (574,35 � 169,20 ?m and 1787,40 � 140,87 ?m, respectively) in IIH patients than healthy individuals (187,18 � 132,15 ?m and 1632,65 � 162,58 ?m, respectively), whereas ALSCD was found to be significantly less in IIH patients (234,49 � 49,31 ?m) than healthy individuals (425,65 � 65,23 ?m). There was not a statistically significant difference regarding LCT between the IIH patients (238,59 � 17,31 ?m) and healthy individuals (244,96 � 15,32 ?m). Conclusion: Increased intracranial pressure causes morphological changes in lamina cribrosa. Assessment of lamina cribrosa with EDI-OCT is important for diagnosis and follow-up of patients with IIH. EDI-OCT is objective, reproducible, and cost-effective assistive imaging tool in IIH patients.

3.
Journal of the Korean Ophthalmological Society ; : 836-845, 2017.
Article in Korean | WPRIM | ID: wpr-65566

ABSTRACT

PURPOSE: To compare the diagnostic capability of Bruch membrane opening-minimum rim width (BMO-MRW) and peripapillary retinal nerve fiber layer (RNFL) thickness for the detection of primary open angle glaucoma. METHODS: Spectral-domain optical coherence tomography (SD-OCT) with 24 radial and 1 peripapillary B-scans centered on the Bruch membrane opening (BMO) was performed. Two SD-OCT parameters were computed globally and sectorally: (1) BMO-MRW, the minimum distance between BMO and internal limiting membrane; and (2) peripapillary retinal nerve fiber layer (RNFL) thickness. The diagnostic performance of BMO-MRW and RNFL thickness were compared with receiver operating characteristic (ROC) analysis globally and sectorally. Areas under the ROC (AUC) were calculated and compared. RESULTS: One hundred fourteen eyes (52 healthy, 62 glaucomatous) of 114 participants were included. In global analyses, the performance of BMO-MRW was similar to that of RNFL thickness (AUC 0.95 [95% confidence interval {CI}, 0.91-0.99], and 0.95 [95% CI, 0.91-0.99], respectively, p=0.93). In sectoral analyses, the pair-wise comparison among the ROC curves showed no statistical difference for all sectors except for the superotemporal, superonasal, and nasal sectors, which had significantly larger AUCs in BMO-MRW compared to RNFL thickness (p=0.03, p<0.001, and p=0.03, respectively). The parameter with the largest AUC was the inferotemporal sector for both BMO-MRW and RNFL thickness (AUC 0.98 [95% CI, 0.96-1.00], and 0.98 [95% CI, 0.96-1.00], respectively, p=0.99). CONCLUSIONS: Global BMO-MRW performed as well as global RNFL thickness for detection of glaucoma. In superotemporal, superonasal and nasal sectors, regional BMO-MRW performed better than regional RNFL thickness.


Subject(s)
Area Under Curve , Bruch Membrane , Glaucoma , Glaucoma, Open-Angle , Membranes , Nerve Fibers , Retinaldehyde , ROC Curve , Tomography, Optical Coherence
SELECTION OF CITATIONS
SEARCH DETAIL